Related Experiment Video
Updated: Jul 3, 2026

Video-rate Scanning Confocal Microscopy and Microendoscopy
Published on: October 20, 2011
Efficient rejection of scattered light enables deep optical sectioning in turbid media with low-numerical-aperture
Jonathan T C Liu1, Michael J Mandella, James M Crawford
1Stanford University, Department of Electrical Engineering, Ginzton Laboratory, and School of Medicine, James H. Clark Center for Biomedical Engineering and Science, Stanford, California 94305, USA. jonliu@stanfordalumni.org
Abstract:
Miniature endoscopic microscopes, with subcellular imaging capabilities, will enable in vivo detection of molecularly-targeted fluorescent probes for early disease detection. To optimize a dual-axis confocal microscope (DACM) design for this purpose, we use a tabletop instrument to determine the ability of this technology to perform optical sectioning deep within tissue. First, we determine how tissue scattering deteriorates the diffraction-limited transverse and vertical responses in reflectance imaging. Specifically, the vertical response of a DACM to a plane reflector is measured at various depths in a scattering phantom and compared with diffraction theory and Monte Carlo scattering simulations. Similarly, transverse line scans across a knife-edge target are performed at various depths in a scattering phantom. Second, as a practical demonstration of deep-tissue fluorescence microscopy that corroborates the findings from our scattering experiments, 3-D fluorescence images are obtained in thick human gastrointestinal mucosal specimens. Our results demonstrate efficient rejection of scattered light in a DACM, which enables deep optical sectioning in tissue with subcellular resolution that can distinguish between normal and premalignant pathologies.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy

