Related Experiment Video
Updated: Jul 3, 2026

Power Input Measurements in Stirred Bioreactors at Laboratory Scale
Published on: May 16, 2018
Gas holdup, power consumption, and oxygen absorption coefficient in a stirred-tank fermentor under foam control
M Yasukawa1, M Onodera, K Yamagiwa
1Department of material and Chemical Engineering, Niigata University, Ikarashi Ni-no-cho, Niigata city 950-21, Japan.
Abstract:
For a laboratory stirred-tank fermentor (STF) with foaming system of 0.5M sulfite solution containing an anionic soft detergent, the performing of a foam-breaking apparatus with a rotating disk (FARD)fitted to the STF was evaluated. The gas holdup in a mechanical foam-control system (MFS), i.e., the stirred-tank fermentor with the rotating disk foambreaker, was confirmed to be larger than that in a nonfoaming system (NS), i.e., the STF with an antifoam agent added. The agitation power in the mechanical foam control system was found to be smaller compared with the agitation power in the nonfoaming system, due to the increased gas holdup. Comparison of the oxygen absorption coefficient between the mechanical foam control system and the nonfoaming system in terms of the specific power input also demonstrated the superiority of the mechanical foam control system, not only in oxygen transfer performance but also in power input economy.
Related Concept Videos
Bioreactor Controls-II
Bioreactor Controls-I
Bioreactor Design and Operational System
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures enhance...
Scale-Up Processes
Production of Alcohol