Related Experiment Video
Updated: Jul 3, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
[Influence of hand-mixed methods on compressive strength of zinc phosphate dental cement]
Hao-Lai Li1, Dan Liu, Xiao-Qin Bi
1Department of Conservative Dentistry and Endodontics, West China College of Stomatology, Sichnan University, Chengdu 610041, China.
Objective:
To study the influence of hand-mixed methods on the compressive strength of the zinc phosphate dental cement.
Methods:
Three skilled nurses used three kinds of common clinical hand-mixed methods (included the unidirectional rotation method, the alternate pro and con bidirectional rotation method and the pulling and pushing with folding method) to mix the zinc phosphate dental cement on the same condition (i.e. same indoor temperature and humidity, the same mixing ratio, mixing time, mixing frequency and the same mixing instruments and so on). The mixed zinc phosphate cement was packed into the plastic cylinders with 10 mm-high and 5 mm-bore. After the mixed zinc phosphate cement coagulated, compressive strength was tested separately.
Results:
The compressive strength of the zinc phosphate dental cement mixed with the alternate pro and con bidirectional rotation method was the best, and the value was (106.11+/- 4.82) MPa. The compressive strength of the zinc phosphate dental cement mixed with the pulling and pushing with folding method was lower, and the value was (77.57 +/- 6.26) MPa. The compressive strength of the zinc phosphate dental cement mixed with the unidirectional rotation method was the lowest, and the value was (54.41 +/- 5.08) MPa. The compressive strength of the zinc phosphate dental cement mixed with the unidirectional rotation method and the pulling and pushing with folding method could not achieve the clinical required compressive strength (about 100 MPa), while the compressive strength mixed with the alternate pro and con bidirectional rotation method was above 100 MPa.
Conclusion:
The alternate pro and con bidirectional rotation method to mix the zinc phosphate dental cement is recommended in clinic.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Bonding and Strength of Aggregate
Testing Water Quality
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Impact Strength of Concrete
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...