The binary dissector: phase contrast tomography of two- and three-material objects from few projections
G R Myers1, T E Gureyev, D M Paganin
1School of Physics, Monash University, VIC 3800, Australia. 3169, Australia. glenn.myers@sci.monash.edu.au
Abstract:
In X-ray computed tomography (CT) increased information requirements (e.g. increased resolution) typically lead to a concurrent increase in the required number of viewing angles, scanning time and delivered dose. We demonstrate that using phase-contrast imaging it is possible to "dissect" two- and three-material objects into their component materials, which in combination with binary tomographic techniques allows us to satisfy increased information requirements without taking the usual images at additional viewing angles. This imaging scheme reduces the scanning time and dose delivered to samples by at least an order of magnitude when compared to conventional X-ray CT. The effects of noise on our reconstruction scheme are investigated for simulated data. Finally, a slice through a glass tube filled with silica and water is reconstructed from 18 projection images taken on an X-ray ultra Microscope (XuM).
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Three-Dimensional Microscopy in Microbiology
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...