Background:
MRI is often used as primary outcome measure in phase II clinical trials in multiple sclerosis (MS). Since persistent T1 hypointense lesions are a surrogate parameter for axonal damage and demyelination, they may serve as a marker for monitoring the efficacy of neuroprotective drugs. At present, a power analysis using black hole (BH) evolution as primary outcome measure has not been performed.
Objective:
To assess the feasibility of using BH evolution on serial brain MR images as primary outcome measure in proof of concept studies in MS.
Methods:
MRI-data obtained from 169 active RRMS patients were analysed for BH evolution by determining the cumulative number of contrast enhancing lesions (CEL) evolving into a persistent black hole (PBH) after 3 months. With a parametric simulation procedure, based on a statistical distribution fitting the data, sample sizes were calculated.
Results:
21.2% of the total number of CELs observed during the study period evolved into a PBH. Ring enhancing lesions evolved most frequently into a PBH (59.4%), followed by lesions larger than 10 mm (57.4%) and periventricular CELs (30.6%). The simulation procedure, based on the statistical negative binomial (NB) model resulted in a sample sizes between 200 subjects and 30 subjects per arm, for treatment effects ranging from 50% to 90% reduction of the number of CELs evolving into a PBH, respectively.
Conclusion:
To perform a MRI monitored phase II clinical trial with a feasible sample size, using the evolution of CELs into PBHs as primary outcome parameter, a potent drug is required to obtain sufficient power.