A study of the reactive intermediate IF and I atoms with photoelectron spectroscopy

Fabrizio Innocenti1, Marie Eypper, Sonya Beccaceci

  • 1Department of Chemistry, University of Southampton, Highfield, Southampton SO17 1BJ, UK.

Related Concept Videos

Energy Diagrams, Transition States, and Intermediates02:13

Energy Diagrams, Transition States, and Intermediates

Free-energy diagrams, or reaction coordinate diagrams, are graphs showing the energy changes that occur during a chemical reaction. The reaction coordinate represented on the horizontal axis shows how far the reaction has progressed structurally. Positions along the x-axis close to the reactants have structures resembling the reactants, while positions close to the products resemble the products.  Peaks on the energy diagram represent stable structures with measurable lifetimes, while other...
Radical Reactivity: Overview01:11

Radical Reactivity: Overview

Radicals, the highly reactive species, gain stability by undergoing three different reactions. The first reaction involves a radical-radical coupling, in which a radical combines with another radical, forming a spin‐paired molecule. The second reaction is between a radical and a spin‐paired molecule, generating a new radical and a new spin‐paired molecule. The third reaction is radical decomposition in a unimolecular reaction, forming a new radical and a spin‐paired molecule. These three...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...