Related Experiment Video
Updated: Jul 3, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Dynamic liquid phase nanoextraction coupled to GC/MS for rapid analysis of methoxyacetophenone and anisaldehyde
1Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, 804, Taiwan. hwu@faculty.nsysu.edu.tw
Abstract:
This study introduces a novel extraction technique in the nanoscale and challenges the limits of solvent extraction in the GC/MS using electronic ionization (EI) method for quantitative determination of six methoxyacetophenone (MAP) and anisaldehye (AAH) isomers in one drop of water and urine. This technique is termed as dynamic liquid phase nanoextraction (DLPNE). The optimum parameters for the DLPNE technique were: selection of solvent, toluene; sampling volume, 0.44 microL; dwell time, 2 s; number of sampling, 15; extraction time, 1.5 min; volume of extraction solvent, 60 nL; and no salt addition. The LODs for this technique were 5-20 ng/mL. The RSDs were in the range of 9.7-12.6% (n = 6). The linear dynamic range of the calibration curve of DLPNE is from 0.02 to 0.5 microg/mL with correlation coefficient (r(2)) >0.9705. The advantages of the DLPNE technique are rapidity, ease of operation, simple device, and extremely little solvent and sample consumption. This technique was also compared with the static liquid phase nanoextraction (SLPNE) while the SLPNE failed to detect any signal for the six isomers. We believe that this technique can be very useful for the detection of volatile organic compounds in environmental science from microscale of water or it can be applied to clinical or pharmaceutical application such as diagnosis of microamount of urine or blood samples by GC/MS.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process