Related Experiment Video
Updated: Jul 3, 2026

A Method for the Measurement of Salivary Gland Function in Mice
Published on: January 25, 2018
Comparison of saliva sampling methods for measurement of salivary adiponectin levels
Masahiro Toda1, Kanehisa Morimoto
1Department of Social and Environmental Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan. mt@envi.med.osaka-u.ac.jp
Abstract:
We measured salivary adiponectin levels in saliva samples collected in two different ways and compared the results. Using the Salivette system, we collected samples from 30 healthy females into test tubes. Salivary adiponectin levels were evaluated using a commercial enzyme immunoassay kit for plasma but with a slightly modified method. While there was a significant correlation between adiponectin levels in plasma and test-tube saliva (p<0.05), no correlation between adiponectin levels in plasma and Salivette-sampled saliva was apparent. These findings suggest that test-tube sampling is more reliable than use of the Salivette system for measuring salivary adiponectin levels.
More Related Videos
08:25Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
08:37Sampling Human Indigenous Saliva Peptidome Using a Lollipop-Like Ultrafiltration Probe: Simplify and Enhance Peptide Detection for Clinical Mass Spectrometry
Published on: August 7, 2012