Related Experiment Video
Updated: Jul 3, 2026

The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
Umbilical venous blood flow measurement: accuracy and reproducibility
F Figueras1, S Fernández, E Hernández-Andrade
1Maternal-Fetal Medicine Department, Obstetrics, Gynaecology and Neonatology Institute, ICGON Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain. ffiguera@clinic.ub.es
Abstract:
Umbilical venous blood flow could be considered a direct and physiological measurement of vascular placental function, representing the quantity of oxygen and nutrients reaching the fetus. The advent of high-technology ultrasound and pulsed Doppler has overcome some of the limitations of early studies. Indeed, Doppler measurement of umbilical venous blood flow has been found to be accurate when compared with several gold standards for in-vivo flow calculation. Nevertheless, small errors in volume flow components, the vessel area and the mean velocity, result in large errors in the calculation of volume flow. Therefore, technique standardization is of paramount importance. Validation studies in animal models have demonstrated accurate venous blood flow measurements by estimating the vessel's cross-sectional area from perpendicular views of longitudinal sections of free-floating portions of the cord. On the other hand, estimation of the mean velocity from the maximum velocity, rather than using the intensity-weighted mean velocity, is less software-dependent and more clearly defined, yielding estimates with more predictable and systematic errors. By adhering to stringent methodological recommendations, umbilical venous blood flow calculation has moderate to good intra- and interobserver reproducibility. Having been found to be accurate and reproducible, further studies are required to establish the clinical value of umbilical vein flow measurement.
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure

