Linear constrain relations in biochemical reaction systems III. Sequential application of data reconciliation for
R T van der Heijden1, B Romein, J J Heijnen
1Unilever Research Laboratory, Oliver van Noortlaan 120, 3133 AT Vlaardingen, The Netherlands.
Abstract:
This article presents a method to test the presence of relatively small systematic measurement errors; e.g., those caused by inaccurate calibration or sensor drift. To do this, primary measurements-flow rates and concentrations-are first translated into observed conversions, which should satisfy several constraints, like the laws of conservation of chemical elements. This study considers three objectives: 1.Modification of the commonly used balancing technique to improve error sensitivity to be able to detect small systematic errors. To this end, the balancing technique is applied sequentially in time.2.Extension of the method to enable direct diagnosis of errors in the primary measurements instead of diagnosing errors in the observed conversions. This was achieved by analyzing how individual errors in the primary measurements are expressed in the residual vector.3.Derivation of a new systematic method to quantitatively determine the sensitivity of the error, is that error size at which the expected value of the chisquare test function equals its critical value.The method is applied to industrial data demonstrating the effectiveness of the approach. It was shown that, for most possible error sources, a systematic errors of 2% to 5% could be detected. In given application, the variation of the N-content of biomass was appointed to be the cause of errors. (c) 1994 John Wiley & Sons, Inc.
Related Concept Videos
Data Validation
Key parameters for method validation include:
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Chemical Equilibria: Systematic Approach to Equilibrium Calculations
The first step is to identify all the chemical reactions involved, The...
Consecutive Reactions
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Measuring Reaction Rates