Eye lens exposure to radiation in interventional suites: caution is warranted
Eliseo Vano1, Luciano Gonzalez, Jose M Fernández
1Department of Radiology, Complutense University, 28040 Madrid, Spain. eliseo@med.ucm.es
Purpose:
To report estimated radiation doses to the eye lens of the interventionalist from procedures performed with and without use of radiation protection measures.
Materials And Methods:
Scattered radiation doses for seven interventional radiology fluoroscopic systems were measured by using phantoms simulating patients 16-28 cm in thickness undergoing low-, medium-, and high-mode fluoroscopy, cine cardiac imaging, and digital subtraction angiography (DSA). The radiation doses to the eye lens in low- and high-dose scenarios were estimated. Beam angulation, biplanar equipment, working distance, procedure complexity, imaging collimation, and use of eyeglasses and/or protective suspended screens were taken into account. The doses to the lens in several procedures were assessed.
Results:
Mean scattered radiation doses to the lens during fluoroscopy were 6.0 and 34.5 microSv/min in the low- and high-dose scenarios, respectively. For DSA, typical doses to the lens ranged from 0.77 to 3.33 microSv per image. Operation modes involving increasing or decreasing radiation doses were quantified. For hepatic chemoembolization, iliac angioplasty, pelvic embolization, and transjugular intrahepatic portosystemic shunt creation, lens doses ranged from 0.25 to 3.72 mSv per procedure when protection was not used. Lens doses in the neuroembolization procedures could exceed 10 mSv per procedure.
Conclusion:
With typical reported workloads, radiation doses to eye lenses may exceed the threshold for deterministic effects (ie, lens opacities or cataracts) after several years of work if radiation protection tools are not used.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging