Related Experiment Video
Updated: Jul 3, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Quantitative analysis of norepinephrine transporter in the human brain using PET with (S,S)-18F-FMeNER-D2
Ryosuke Arakawa1, Masaki Okumura, Hiroshi Ito
1Molecular Neuroimaging Group, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba, Japan.
Unlabelled:
(S,S)-18F-FMeNER-D2 was recently developed as a radioligand for the measurement of norepinephrine transporter imaging with PET. In this study, a norepinephrine transporter was visualized in the human brain using this radioligand with PET and quantified by several methods.
Methods:
PET scans were performed on 10 healthy men after intravenous injection of (S,S)-18F-FMeNER-D2. Binding potential relative to nondisplaceable binding (BP(ND)) was quantified by the indirect kinetic, simplified reference-tissue model (SRTM), multilinear reference-tissue model (MRTM), and ratio methods. The indirect kinetic method was used as the gold standard and was compared with the SRTM method with scan times of 240 and 180 min, the MRTM method with a scan time of 240 min, and the ratio method with a time integration interval of 120-180 min. The caudate was used as reference brain region.
Results:
Regional radioactivity was highest in the thalamus and lowest in the caudate during PET scanning. BP(ND) values by the indirect kinetic method were 0.54 +/- 0.19 and 0.35 +/- 0.25 in the thalamus and locus coeruleus, respectively. BP(ND) values found by the SRTM, MRTM, and ratio methods agreed with the values demonstrated by the indirect kinetic method (r = 0.81-0.92).
Conclusion:
The regional distribution of (S,S)-18F-FMeNER-D2 in our study agreed with that demonstrated by previous PET and postmortem studies of norepinephrine transporter in the human brain. The ratio method with a time integration interval of 120-180 min will be useful for clinical research of psychiatric disorders for estimation of norepinephrine transporter occupancy by antidepressants without requiring arterial blood sampling and dynamic PET.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET