Long-term pressure monitoring with arterial applanation tonometry: a non-invasive alternative during clinical
Koen S Matthys1, Alain F Kalmar, Michel M R F Struys
1School of Engineering and Design, Brunel University, London, UK. koen.matthys@brunel.ac.uk
Abstract:
Arterial tonometry is a non-invasive technique for continuous registration of arterial pressure waveforms. This study aims to assess tonometric blood pressure recording (TBP) as an alternative for invasive long-term bedside monitoring. A prospective study was set up where patients undergoing neurosurgical intervention were subjected to both invasive (IBP) and non-invasive (TBP) blood pressure monitoring during the entire procedure. A single-element tonometric pressure transducer was used to better investigate different inherent error sources of TBP measurement. A total of 5.7 hours of combined IBP and TBP were recorded from three patients. Although TBP performed fairly well as an alternative for IBP in steady state scenarios and some short-term variations, it could not detect relevant long-term pressure variations at all times. These findings are discussed in comparison to existing work. Physiological alterations at the site of TBP measurement are highlighted as a potentially important source of artifacts. It is concluded that at this point arterial tonometry remains not enough understood for long-term use during a delicate operative procedure. Physiological changes at the TBP measurement site deserve further investigation before tonometry technology is to be considered as an non-invasive alternative for long-term clinical monitoring.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure