High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Highly iodinated intravenous contrast material for PET/CT - a feasibility study
T A Heusner1, H Kuehl, P Veit-Haibach
1Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Germany.
Highly concentrated contrast media (HCCM) is feasible for PET/CT imaging, showing no significant impact on tracer uptake or artifacts. HCCM enhances CT attenuation, aiding PET attenuation correction in nuclear medicine.
Area of Science:
- Nuclear Medicine
- Radiology
- Medical Imaging
Background:
- Intravenous contrast materials (CM) improve PET/CT imaging but can affect tracer quantification and introduce artifacts.
- CT-based attenuation correction in PET/CT is crucial for accurate quantitative analysis.
Purpose of the Study:
- To evaluate the feasibility of using highly concentrated contrast media (HCCM, 400 mg iodine/ml) in PET/CT.
- To compare HCCM with lower concentrated contrast media (LCCM, 300 mg iodine/ml) regarding tracer quantification and image artifacts.
Main Methods:
- 60 whole-body FDG PET/CT scans were analyzed (30 with HCCM, 30 with LCCM).
- Tracer uptake (SUVmax) and CT attenuation (Hounsfield Units) were quantified at 16 anatomical positions.
- The incidence of potential PET artifacts was documented and statistically analyzed using the Mann-Whitney-Wilcoxon Test.
Main Results:
- HCCM did not significantly increase SUVmax (p > 0.05) or the number of PET artifacts (p = 0.69) compared to LCCM.
- HCCM significantly increased CT attenuation (p = 0.002) in 11 out of 16 positions.
Conclusions:
- The use of HCCM in PET/CT appears feasible and safe.
- HCCM warrants consideration for future PET/CT imaging protocols due to its potential benefits in attenuation correction.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...