Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 3, 2026

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

Ultralow-power electronics for biomedical applications.

Anantha P Chandrakasan1, Naveen Verma, Denis C Daly

  • 1Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. anantha@mtl.mit.edu

Annual Review of Biomedical Engineering
|July 24, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Portable, real-time 3D ultrasound for operator-independent breast imaging.

Nature communications·2026
Same author

Diagnostic anatomy of the head region of Beetal goat and Kajali sheep with special reference to its importance in regional anaesthesia.

Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft·2026
Same author

Real-Time 3D Ultrasound Imaging with an Ultra-Sparse, Low Power Architecture.

Advanced healthcare materials·2026
Same author

Physiochemical and transcriptional reprogramming of mild salinity mediated modulation of Steviol Glycoside biosynthesis in Stevia rebaudiana Bertoni.

Plant physiology and biochemistry : PPB·2026
Same author

Acute vision loss associated with vincristine therapy in T cell lymphoma.

BMJ case reports·2025
Same author

An Analog Front-End for Bladder Ultrasound Monitoring: Achieving 75% Reduction in RX Power Consumption through Power Gating for Intra-Image Sparsity.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Physics-Informed Machine Learning in Biomedical Science and Engineering.

Annual review of biomedical engineering·2026
Same journal

Advancements and Challenges in Computer-Assisted Medical Interventions for Image-Guided Prostate Cancer Treatments.

Annual review of biomedical engineering·2026
Same journal

Recent Advances in mRNA Therapeutic Cancer Vaccines.

Annual review of biomedical engineering·2026
Same journal

Artificial Intelligence-Based Analysis of Laparoscopic Imaging for Intraoperative Surgical Decision Support.

Annual review of biomedical engineering·2026
Same journal

Viscoelasticity of the Heart: An Overview of Viscoelastic Measurements at Different Scales.

Annual review of biomedical engineering·2026
Same journal

Digital Twins for Biofluids.

Annual review of biomedical engineering·2026
See all related articles

This study presents low-power circuit techniques for biomedical devices, focusing on energy efficiency and harvesting. These advancements enable sophisticated systems operating at microwatt power levels for enhanced user lifestyle.

Area of Science:

  • Biomedical Engineering
  • Electrical Engineering
  • Low-Power Electronics Design

Background:

  • Biomedical devices require minimal energy consumption for subsystems like energy delivery, analog-to-digital conversion, signal processing, and communication.
  • Stringent energy constraints are dictated by the energy source, highlighting the importance of energy harvesting.

Purpose of the Study:

  • To outline the performance and power constraints of biomedical devices.
  • To present circuit techniques for achieving complete systems operating at microwatt power levels.
  • To emphasize approaches leveraging advanced technology trends for low-power biomedical systems.

Main Methods:

  • Employing specific design techniques such as aggressive voltage scaling, dynamic power-performance management, and energy-efficient signaling.

More Related Videos

Wideband Optical Detector of Ultrasound for Medical Imaging Applications
08:21

Wideband Optical Detector of Ultrasound for Medical Imaging Applications

Published on: May 11, 2014

Related Experiment Videos

Last Updated: Jul 3, 2026

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
08:25

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver

Published on: August 27, 2021

Wideband Optical Detector of Ultrasound for Medical Imaging Applications
08:21

Wideband Optical Detector of Ultrasound for Medical Imaging Applications

Published on: May 11, 2014

  • Addressing the challenges of efficient low-energy delivery and robust operation in aggressive low-power modes.
  • Leveraging advanced technology trends in circuit design.
  • Main Results:

    • Demonstration of circuit techniques enabling complete biomedical systems to operate at microwatt power levels.
    • Successful adherence to stringent energy constraints through optimized design strategies.
    • Identification of design limitations and solutions for aggressive low-power operation.

    Conclusions:

    • Sophisticated biomedical systems can be enabled through energy harvesting and efficient low-power design.
    • Advanced circuit techniques are crucial for meeting the energy demands of modern biomedical devices.
    • Future biomedical device development should prioritize energy efficiency and leverage emerging technologies.