Related Experiment Video
Updated: Jul 3, 2026

Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Analysis of ciprofloxacin by a simple high-performance liquid chromatography method
Shihn-Sheng Wu1, Chih-Yuan Chein, Yen-Hsia Wen
1Pharmacy School, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan.
A new high-performance liquid chromatography method accurately quantifies ciprofloxacin in pharmaceuticals and human plasma. This sensitive technique is valuable for pharmacokinetic studies and drug analysis.
Area of Science:
- Analytical Chemistry
- Pharmacokinetics
- Pharmaceutical Analysis
Background:
- Ciprofloxacin is a widely used fluoroquinolone antibiotic.
- Accurate quantification of ciprofloxacin in biological matrices and pharmaceutical formulations is crucial for therapeutic drug monitoring and pharmacokinetic studies.
- Existing analytical methods may lack sensitivity, require complex sample preparation, or are time-consuming.
Purpose of the Study:
- To develop and validate a simple, sensitive, and rapid high-performance liquid chromatographic (HPLC) method for the quantitative analysis of ciprofloxacin.
- To determine the linearity, accuracy, precision, and recovery of the developed HPLC method for ciprofloxacin in pharmaceutical samples and human plasma.
- To apply the validated method in a pharmacokinetic study.
Main Methods:
- Reversed-phase HPLC using an RP-C18 column.
- Isocratic mobile phase: acetonitrile-2% acetic acid aqueous solution (16:84, v/v).
- UV detection at 280 nm with umbelliferone as the internal standard.
- Flow rate: 1.0 mL/min.
- Limit of detection (LOD): 0.25 µM.
Main Results:
- Linearity (r > 0.9999) was achieved over wide concentration ranges (0.51–130 µM for pharmaceuticals, 0.51–64.8 µM for plasma).
- Intra- and inter-day precision (relative standard deviation) were <3.39%, and accuracy (relative error) were <5.71%.
- Recovery rates exceeded 93.8% for both sample types.
- The method demonstrated high sensitivity with a low LOD of 0.25 µM.
- Successful application in a pharmacokinetic study of ciprofloxacin administration.
Conclusions:
- The developed HPLC method is simple, sensitive, and accurate for quantifying ciprofloxacin.
- This method is suitable for both pharmaceutical analysis and pharmacokinetic studies involving human plasma.
- The method's efficiency and reliability make it a valuable tool for clinical and research applications.
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
Principles Of Column Chromatography