Which Iodine concentration in chest CT?--a prospective study in 300 patients
Related Experiment Video
Updated: Jul 3, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Georg Mühlenbruch1, Florian F Behrendt, Mohammed A Eddahabi
1Department of Diagnostic and Interventional Radiology, RWTH Aachen University Hospital, Aachen, Germany. gmuehlen@rad.rwth-aachen.de
Insights
This study found no significant difference in chest CT contrast enhancement using 300, 370, or 400 mg iodine/ml contrast media. However, higher iodine concentrations may reduce patient discomfort after injection.
Area of Science:
- Radiology
- Medical Imaging
- Contrast Media
Background:
- Computed tomography (CT) utilizes various contrast media with differing iodine concentrations.
- Optimizing contrast media selection is crucial for diagnostic accuracy in chest CT examinations.
Purpose of the Study:
- To prospectively compare the efficacy and safety of iodinated contrast media with concentrations of 300, 370, and 400 mg iodine/ml for chest CT.
- To evaluate intravascular enhancement, image quality, and patient-reported discomfort across different contrast concentrations.
Main Methods:
- A prospective study involving 300 patients undergoing chest CT.
- Patients received contrast media with 300, 370, or 400 mg iodine/ml, with adapted injection protocols for identical iodine delivery rate (1.3 mg/s) and total iodine load (33 g).
- Intravascular attenuation was measured in the pulmonary trunk and ascending aorta; subjective image quality and patient discomfort were assessed.
Main Results:
- No statistically significant differences in contrast enhancement were observed in the pulmonary trunk (p = 0.3198) or ascending aorta (p = 0.0840) among the three contrast media groups.
- Subjective image quality (p = 0.0176) and discomfort during injection (p = 0.7034) were comparable across all groups.
- General discomfort after injection was significantly higher for the 300 mg iodine/ml group compared to the 370 mg iodine/ml group (p = 0.00019).
Conclusions:
- Contrast media concentrations of 300, 370, and 400 mg iodine/ml yield comparable intravascular enhancement in chest CT when iodine delivery rates and loads are identical.
- Higher iodine concentrations (e.g., 370 mg/ml) may be associated with reduced post-injection patient discomfort.
- The choice of contrast media concentration in chest CT can be guided by both diagnostic efficacy and patient tolerance.
Abstract:
In computed tomography (CT) several contrast media with different iodine concentrations are available. The aim of this study is to prospectively compare contrast media with iodine concentrations of 300, 370 and 400 mg iodine/ml for chest- CT. 300 consecutive patients were prospectively enrolled, under a waiver of the local ethics committee. The first (second, third) 100 patients, received contrast medium with 300 (370, 400) mg iodine/ml. Injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and total iodine load (33 g) for all three groups. Standardized MDCT of the chest (16 x 0.75 mm, 120 kVp, 100 mAseff.) was performed. Intravascular attenuation values were measured in the pulmonary trunk and the ascending aorta; subjective image quality was rated on a 3-point-scale. Discomfort during and after injection was evaluated. There were no statistically significant differences in contrast enhancement comparing the three contrast media at the pulmonary trunk (p = 0.3198) and at the ascending aorta (p = 0.0840). Image quality (p = 0.0176) and discomfort during injection (p = 0.7034) were comparable for all groups. General discomfort after injection of contrast media with 300 mg iodine/ml was statistically significant higher compared to 370 mg iodine/ml (p = 0.00019). Given identical iodine delivery rates of 1.3 g/s and iodine loads of 33 g, contrast media with concentrations of 300, 370 and 400 mg iodine/ml do not result in different intravascular enhancement in chest-CT.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Redox Titration: Iodimetry and Iodometry
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...