Related Experiment Video
Updated: Jul 3, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Choice of echocardiography method for postoperative evaluation of mitral valve replacement with a mechanical
G Greffe1, R Henaine, O Metton
1Département de chirurgie cardiaque et transplantation, Hôpital Cardiothoracique Louis-Pradel, Lyon-Bron.
Object:
The French Cardiology Society (SFC) systematically recommends (Class I) transesophageal echocardiography (TEE) after any mitral valve replacement with a mechanical prosthesis (MMVR). Taking into account the increasing workload of echocardiography laboratories, our attitude was to propose that only post-operative transthoracic echocardiography (TTE) is performed. The purpose of this study was to evaluate the possible risks of this simplified procedure.
Methods:
We performed a precise analysis of one full year of practice of MMVR with exhaustive follow-up for the first 2 years concentrating on thromboembolic complications.
Results:
From January to December 2003, 84 MMVRs (46 after rheumatic fever, 22 degenerative disease, 11 infective endocarditis (IE) and 5 ischemia) were conducted in 45 women and 39 men of average age 61 years. Early mortality (<30 days) concerned 5 patients (5.9%). A control TTE to determine normal prosthetic function was performed 7+/-2 days after surgery and this revealed 2 cases of nonobstructive thrombosis which were treated medically, 3 cases of paraprosthetic regurgitation, and 1 vegetation due to underlying IE. Actuarial survival was 90.5% at 1 year and 83.3% at 2 years. After a mean follow-up of 179.3 patient-years, 5 patients were reoperated (5.9%): 1 for IE, 1 for paravalvular regurgitation, 1 for mitral valve insufficiency with haemolysis, and 2 for obstructive prosthetic valve thromboses. In addition there were 2 cases of prosthetic valve thrombosis, 8 ischemic strokes (2 ministrokes, 6 sequelar strokes), and 1 peripheral embolism. The global thromboembolic complication rate was therefore 6.1 per 100 patient-years (n=11). There were 4 hemorrhagic events, i.e. a rate of 2.2 events per 100 patient-years. 63% of the 1193 INR conducted were within the target range (3-4.5), 26% were below 3 and 11% were greater than 4.5. 35% of patients with thromboembolic complications had an INR<3.
Conclusion:
Morbidity and mortality during the first 2 years after MMVR were relatively high but equivalent to the values of comparable series in the literature. These complications would not have been reduced by a more precise screening based on early TEE. Despite the increasingly litigious nature of the doctor-patient relationship, it would probably be excessive to oppose that this guideline was not followed in a dispute; in particular as it is difficult to apply this measure as echocardiography departments are overworked.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis III: Medical Management
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies