Optimization of patent foramen ovale detection by contrast transthoracic echocardiography using second harmonic
J Lefèvre1, S Lafitte, P Reant
1Laboratoire d'échographie cardiaque, Hôpital Cardiologique du Haut-Levêque, Université de Bordeaux 2, Pessac.
Background:
Patent foramen ovale is an anomaly responsible for paradoxical embolizations and cerebral ischemic events. Aims. - We want to show second harmonic transthoracic echography sensitized by contrast agent perfusion is as well as transesophageal echography to patent foramen ovale detection.
Methods:
Onene hundred twenty one patients referred for transesophageal echocardiography for patent foramen ovale detection, underwent additive second harmonic transthoracic echocardiography with one of three randomized contrast agents: a mixture A of dextrose and air, mixture B of dextrose and air and blood, or mixture C of hydroxyethylamidon. The severity of atrial shunting was evaluated on recordings by semi-quantitative scoring. Intensity of contrast was also assessed by objective quantitative videodensitometry.
Results:
No difference was observed between the two techniques, nor between mixture A, B and C in terms of PFO detection during each exam. However, quantitative contrast analysis showed higher intensity with mixtures B and C with mixture A during transthoracic echography.
Conclusions:
When performed with a contrast agent, second harmonic transthoracic echography and transoesophageal echography are comparable when it comes to patent foramen ovale detection. Although the composition of the contrast agent does not appear to affect the rate of this detection, contrast quality in the right atrium during transthoracic exam is better with mixtures B and C than with mixture A.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Mitral Stenosis II: Clinical features and Diagnostic Tests