Related Experiment Video
Updated: Jul 3, 2026

Standardized Rat Coronary Ring Preparation and Real-Time Recording of Dynamic Tension Changes Along Vessel Diameter
Published on: June 16, 2022
Coronary pressure never lies
Jacques J Koolen1, Nico H J Pijls
1Department of Cardiology, Catharina Hospital Eindhoven, 5602 ZA, Eindhoven, The Netherlands.
Insights
Fractional Flow Reserve (FFR) is the gold standard for assessing coronary stenosis significance. This report discusses rare cases where FFR results initially seem incorrect but are explained by underlying physiology.
Area of Science:
- Cardiology
- Interventional Cardiology
- Physiology
Background:
- Fractional Flow Reserve (FFR) is the invasive gold standard for evaluating coronary artery stenosis.
- It determines hemodynamic significance and guides percutaneous coronary intervention (PCI).
- FFR accuracy in identifying ischemia-causing lesions is high, with rare false positives/negatives.
Observation:
- This case report details two instances where initial FFR measurements appeared contradictory to clinical intuition.
- These discrepancies arose in specific clinical or angiographic scenarios.
- The interventionalist's initial assessment was challenged by the FFR data.
Findings:
- Further investigation revealed clear physiological explanations for the seemingly discordant FFR values.
- Apparent false positive or negative FFR results were elucidated through deeper analysis.
- FFR, when properly interpreted, often clarifies complex hemodynamic situations.
Implications:
- Understanding these physiological nuances is crucial for accurate FFR interpretation.
- FFR can 'lift the veil' on complex coronary physiology, preventing inappropriate interventions.
- This highlights the importance of integrating FFR data with clinical judgment and physiological understanding.
Abstract:
Fractional Flow Reserve (FFR), calculated by coronary pressure measurement, is the invasive gold standard to assess the hemodynamic significance of a coronary stenosis. FFR reliably indicates whether a stenosis is responsible for inducible ischemia and if percutaneous coronary intervention is appropriate. False positive or negative FFR is rare. Occasionally, however, a clinical or angiographic condition is encountered in which in first instance the FFR measurement contradicts the intuitive feeling of the interventionalist. Further examination in such cases, however, often reveals a clear physiologic explanation and in this manner FFR "lifts the veil". Two such patients are presented in this case report and the reasons for apparent or actual false positive or negative FFR are discussed.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Coronary Artery Disease IV: Preventive Measures
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...