[Reduced gas-flow inhalation anesthesia in traumatology and orthopedics]
Abstract:
Whether reduced gas-flow inhalational anesthesia using sevorane might be used in traumatological and orthopedic care was studied. A hundred and thirty-six reduced gas-flow anesthetic aids were applied. These included 41 aids during high risk surgical interventions (ventral spondylodesis under artificial pneumothorax; two-stage surgical interventions in thoracic and thoracolumbar injuries; total knee joint endoprosthesis, corrective osteotomy and synthesis in limb fractures), 66 aids during moderate-risk ones (transpedicular fixation, total hip joint endoprosthesis, intervertebral herniotomy), and 30 aids during low-risk ones (interbody spondylodesis in cervical spinal injuries, hardware removal, arthroscopy, etc.). Under low-flow anesthesia, the parameters of oxygenation, gas exchange, respiratory function, and hemodynamics were beyond the normal physiological values. The developed procedure makes it possible to employ reduced gas-flow inhalational anesthesia using sevorane at the maximum allowable concentration of 0.8 for traumatological and orthopedic operations. The use of sevorane for anesthetic maintenance reduces a pharmacological load on the patient's homeostasis and the synergism with a central analgesic (fentanyl) and a myorelaxant diminishes both a stress-induced response to surgical aggression and an anesthetic agent. Reduced gas-flow anesthesia promotes the exclusion of intraoperative cold gas cooling that is typical of high-flow anesthesia. It is necessary to continue studies to comparatively analyze the consumables in compliance with the requirements for the quality of high-technology surgical interventions since the application of high-grade disposable consumables reduces airway microbial contamination, the time of disinfection of anesthesia-monitoring apparatuses and the consumption of disinfectant agents.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Inhalational Anesthetics: Overview
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...