Introduction of an embolus detection system based on analysis of the transcranial Doppler audio-signal
R W M Keunen1, R Hoogenboezem, R Wijnands
1Department of Neurology and Clinical Neurophysiology, Haga Teaching Hospitals (location Leyenburg), The Hague, The Netherlands. keunenrwm@tiscali.nl
Abstract:
A new embolus detection system (EDS) is presented, built with the intention of detecting ongoing cerebral embolization in patients at risk of transient ischaemic attacks or stroke. It is based on the analysis of the audio-Doppler signal of a transcranial Doppler machine. The algorithm of the EDS estimates the intensity, duration and zero-crossing dynamics of the audio signal. The EDS has a multi-layer neural network which classifies events into micro-emboli signals (MES) or artefacts. The decision-making component of the software has been validated against human experts. Data from patients in the post-operative phase of carotid surgery were used for the validation process. The results showed agreement in MES and artefact classification of > 93%. Apart from a monitoring display, the monitoring system includes a verification unit that allows the user to listen and to look at all data of individual MES and artefacts. Moreover, the system allows the user to record, store and re-calculate all data files. Data are stored using European Data Format, which allows data transportation over the Internet. The EDS may have a potential in stroke risk stratification, evaluating the effect of novel anti-thrombotic therapies, and in peri-operative and remote monitoring of carotid endarterectomy.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: