Insensible water loss from the Jostra Quadrox D oxygenator: an in vitro study
1Duke University Health System, Durham, NC 27710, USA. Lawso008@mc.duke.edu
Abstract:
Extracorporeal membrane oxygenation (ECMO) has been shown to improve outcomes in neonatal patients with respiratory and/or cardiac failure. Insensible water loss is defined as water loss via evaporation from the skin and respiration. Fluid and electrolyte balance are a primary concern and very challenging in the neonatal patient population. Hypernatremia can result from untreated insensible water loss, leading to possible cerebral complications. A new type of fiber used in the Jostra Quadrox D oxygenator has recently been approved for use in the United States of America. This oxygenator uses a polymethylpentene closed hollow-fiber technology and has been approved for six hours of continuous use by the Federal Drug Administration. The closed hollow-fiber technology may be advantageous for extended use due to the fact that it is a true membrane and plasma leakage will not occur across its surface. The Jostra Quadrox D is an adult-sized oxygenator with a surface area of 1.8 M(2). The aim of this study is to discover what the insensible water loss will be from the Jostra Quadrox D when used at blood flows which would mimic those used for a neonatal ECMO patient. The median insensible water loss from the Quadrox D oxygenator at a gas flow rate of two liters per minute(LPM) was 4.0 +/- 0.2 ml/hour, at five LPM was 9.8 +/- 0.4 ml/hour and at 10 LPM was 20.6 +/- 0.7 ml/hour. The daily evaporative water loss from the Jostra Quadrox D can be estimated to be 48.0 +/- 2.1 ml for each LPM of sweep gas with a normal saline pump flow rate of 500 ml/min.
More Related Videos
Related Concept Videos
Adaptations that Reduce Water Loss
Body Water Content and Fluid Compartments
Regulation of Water Output
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...