Arterial switch operation: troponin T does not predict ventilation requirements
Madan M Maddali1, John Valliattu, Taha Al Delamie
1Departments of Anesthesia and Cardiothoracic Surgery, Royal Hospital, Seeb, Muscat, Sultanate of Oman. madan@omantel.net.om
Abstract:
The aim of this study was to assess whether postoperative cardiac troponin T levels could predict ventilation requirements in infants undergoing the arterial switch operation. Cardiac troponin T was measured 6 hours after aortic cross clamping and prior to tracheal extubation in 20 consecutive patients; 10 had simple and 10 had complex (with ventricular septal defect) transposition of the great arteries. The mean plasma troponin T level prior to extubation did not differ significantly in patients who were re-intubated and those who were successfully extubated. The initial cardiac troponin T levels in the complex defect group was significantly higher than in the simple transposition group. There was no correlation between initial cardiac troponin T levels and the duration of mechanical ventilation. There was no difference in mean duration of ventilation between the 2 groups. It was concluded that the postoperative cardiac troponin T level is not a predictor of successful extubation or prolonged artificial ventilation in this subset.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...