Related Experiment Video
Updated: Jul 3, 2026

Personalized Peptide Arrays for Detection of HLA Alloantibodies in Organ Transplantation
Published on: September 6, 2017
Preimplantation HLA haplotyping using tri-, tetra-, and pentanucleotide short tandem repeats for HLA matching
Sarah L Bick1, David P Bick, Brent E Wells
1Division of Medical Genetics, Department of Pediatrics, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
Purpose:
To aid couples wishing to conceive children who are HLA matched to a sibling in need of a hematopoietic progenitor cell transplant, we developed a preimplantation HLA haplotype analysis of embryos that utilizes tri-, tetra-, and pentanucleotide STR markers.
Methods:
For preimplantation HLA genotyping, we use polymorphic STR markers located across the HLA and flanking regions, selecting exclusively tri-, tetra-, and pentanucleotide repeats. These markers can be resolved using either capillary electrophoresis (CE) or polyacrylamide gels.
Results:
We have developed 43 reliable STR markers for preimplantation HLA matching. Selected STR markers enabled unambiguous identification of embryos whose HLA haplotypes were matched with the affected patient using polyacrylamide gel or capillary electrophoresis.
Conclusions:
The use of tri-, tetra-, and pentanucleotide repeat markers and polyacrylamide gels for STR genotyping in HLA matching is a simple and cost effective approach to clinical testing.