Related Experiment Video
Updated: Jul 3, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Fracture resistance of Class II glass-ionomer cement restorations
Terezinha Jesus Esteves Barata1, Eduardo Bresciani, Ticiane Cestari Fagundes
1Department of Operative Dentistry, University of North of Paraná, Brazil.
Purpose:
To investigate in vitro the effect of retentive grooves, GIC type and insertion method on the fracture resistance of Class II glass-ionomer cement (GIC) restorations.
Methods:
Premolars were divided into 12 groups (n = 10) according to three variables: retentive grooves [presence (PR) or absence AR)], GICs type [Ketac-Molar (KM), Fuji VIII (F8) and RelyX Luting (RX)], and insertion method [syringe injector (SI) or spoon excavator (SE)]. The specimens were subjected to fracture resistance test. Data were submitted to three-way ANOVA and multiple comparisons were performed using a Tukey test (P < 0.05).
Results:
Mean fracture resistance values (Kgf) +/- standard deviations (SD) were: KM (PR+SI) = 65.66 +/- 2.5; KM (PR+SE) = 62.58 +/- 2.1; KM (AR+SI) = 57.11 +/- 1.9; KM (AR+SE) = 51.94 +/- 2.3; F8 (PR+SI) = 63.05 +/- 2.1; F8 (PR+SE) = 60.12 +/- 2.3; F8 (AR+SI) = 55.11 +/- 1.9; F8(AR+SE) = 49.20 +/- 1.6; RX (PR+SI) = 50.99 +/- 2.4; RX (PR+SE) = 48.81 +/- 2.5; RX (AR+SI) = 45.53 +/- 2.6; RX (AR+SE) = 41.88 +/- 3.0. Statistically significant differences were observed among all the groups tested (P = 0.001). There was significant difference when pooled means for GIC type were compared with retentive grooves (P = 0.01) and when pooled means for retentive grooves were compared with insertion method (P = 0.01).
Related Concept Videos
Stress-Strain Diagram - Brittle Materials
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Fiber Reinforced Concrete
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bonding and Strength of Aggregate