Related Experiment Video
Updated: Jul 3, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Development of a countergradient parking system for gradient liquid chromatography with online biochemical detection
Nils Helge Schebb1, Ferry Heus, Thorsten Saenger
1Westfalische Wilhelms-Universitat Munster, Institut fur Anorganische and Analytische Chemie, Corrensstrasse 30, 48149 Munster, Germany.
Abstract:
A gradient HPLC approach in combination with a countergradient system for online biochemical detection (BCD) to screen for inhibitors of serine proteases is described. For gradient separations, this novel countergradient system was developed to produce a biocompatible constant solvent composition in the BCD. The countergradient system is based on retaining complete gradients in an additional preparative HPLC column, followed by subsequent and reversible elution to the separation column effluent. Major advantages compared with existing countergradient systems are that no additional LC pumps are needed and enhanced stability. The developed countergradient system was systematically characterized applying different gradient programs. Inhibitors eluting in a postcolumn continuous flow analysis interfere with the enzymatic release of fluorescent 7-amino-4-methylcoumarin (AMC) from an AMC-labeled peptide. The inhibitory activity of eluting substances is sensitively detected as the degree of reduced fluorescence intensity. This biochemical detection system (BCD) for proteases was validated with three known inhibitors of the benzamidine type. Their IC 50 values were in good accordance with the results of conventional plate reader assays. Finally, a small library of protease inhibitors was successfully screened with the combination of the BCD and the countergradient system.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...