Related Experiment Video
Updated: Jul 3, 2026

Continuous Hydrologic and Water Quality Monitoring of Vernal Ponds
Published on: November 13, 2017
A low-tech, low-cost passive sampler for the long-term monitoring of phosphate loads in rivers and streams
Beat Müller1, Ruth Stierli, René Gächter
1Swiss Federal Institute for Environmental Science and Technology, Eawag, CH-6047, Kastanienbaum, Switzerland. beat.mueller@eawag.ch
Abstract:
The concentration of dissolved reactive phosphorus (DRP) in rivers can change intermittently within minutes depending on the weather and water discharge (Q), or activities in the watershed. Accordingly, accurate estimation of the annual DRP load requires frequent sampling or even continuous monitoring, which is laborious and cost-intensive. We present the design and laboratory evaluation of a new, robust, low-cost, low-tech device based on passive samplers (P-traps). The traps use Fe-(oxy)hydroxide coated quartz sand as an adsorbent enclosed in a vertical grid of individual cells separated from the river water by filter membranes. They are inexpensive, easy to handle, resistant to repeated desiccation and immersion and exposable for several months. They permit estimation of discharge dependent time weighted average DRP concentrations (C-Q relationships) and annual P loads of rivers characterized by highly variable DRP concentrations with a relative accuracy of +/- 3%.