Related Experiment Video
Updated: Jul 2, 2026

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Electrochemical behavior of ascorbic acid at a 2,2'-[3,6-Dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone
Zahra Taleat1, Mohammad Mazloum Ardakani, Hossein Naeimi
1Department of Chemistry, Faculty of Science, Yazd University, Iran.
Abstract:
Electrocatalytic oxidation of ascorbic acid (AA) at a carbon paste electrode, chemically modified 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone, was thoroughly investigated. The results of cyclic voltammetry, double potential-step chronoamperometry, linear sweep voltammetry and differential pulse voltammetry (DPV) studies were used for the prediction of the mechanism of electrochemical oxidation of AA mediated with 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone at the surface of the modified electrode. The diffusion coefficient (D = 2.45 x 10(-5) cm(2) s(-1)) and the kinetic parameters such as the electron transfer coefficient (alpha = 0.34) were also determined. The results of DPV using the 2,2'-[3,6-dioxa-1,8-octanediylbis(nitriloethylidyne)]-bis-hydroquinone-modified electrode were applied in a highly sensitive determination of AA in drug samples. A linear range of 3.0 x 10(-6) - 1.2 x 10(-4) M and the detection limit (3sigma) 3.8 x 10(-7) M were obtained for DPV determination of AA in buffered pH 7.00 solutions (0.1 M phosphate buffer).
More Related Videos
08:31Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope (AFM-SECM)
Published on: February 10, 2021
10:48Electrochemical Preparation of Poly(3,4-Ethylenedioxythiophene) Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Related Concept Videos
Polyprotic Acids
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Membrane Electrodes
Electrochemical Cells
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...