Kinetic plot and particle size distribution analysis to discuss the performance limits of sub-2 microm and supra-2

Deirdre Cabooter1, Jeroen Billen, Herman Terryn

  • 1Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, Brussels, Belgium.

Related Concept Videos

Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
Precipitate Formation and Particle Size Control01:16

Precipitate Formation and Particle Size Control

In precipitation gravimetry, the precipitating agent should react specifically or selectively with the analyte. While a specific reagent reacts with the analyte alone, a selective reagent can react with a limited number of chemical species.
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and solvents...
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Plate Theory01:10

Column Efficiency: Plate Theory

Band broadening in a chromatography column is measured by its efficiency. This is determined by the number of theoretical plates (N). Theoretical plate theory states that a separation column consists of a continuous series of imaginary plates where solute equilibration occurs between stationary and mobile phases.
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...