Kinetic plot and particle size distribution analysis to discuss the performance limits of sub-2 microm and supra-2
Deirdre Cabooter1, Jeroen Billen, Herman Terryn
1Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, Brussels, Belgium.
Abstract:
To contribute to the current debate about the "ideal" particle size range (sub-2 microm vs. supra-2 microm), the present study compares the kinetic performance of some commercially available sub-2 microm and 3.5 microm particles used under quasi-adiabatic conditions via the kinetic plot method. Under the adopted assumption that viscous heating effects can be neglected (which is uncertain in a pressure range above 400 bar), the obtained kinetic plots show that, provided each particle size is used in a column with properly optimized length, the gain in separation speed that sub-2 microm particle columns might have over maximally performing 2.5 microm particle columns is very small. Sub-2 microm particle columns can only yield a gain in separation speed in the range of high-speed/low-resolution-separations (total time based on k=10 below 5 or 10 min). And even in this range, the actual gain that can be expected is only marginally small (only a few %). The present study hence suggests that the development and the use of particles in the 2-3 microm range should deserve more attention than it did in the past few years. However, to be competitive, this 2-3 microm material should be packed in relatively long columns, with a packing quality matching that of the current best performing 3.5 microm particle columns. The supra-2 microm particles should also be able to withstand the same pressures as the sub-2 microm particle material one is comparing it to.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...