Assessment of cardiac output in liver transplantation recipients
Tomohide Hori1, Chiduru Yamamoto, Shintaro Yagi
1Department of Hepato-Pancreato-Biliary Surgery and Transplantation, Kyoto University Hospital, Sakyo-ku, Kyoto, 606-8507, Japan. horit@kuhp.kyoto-u.ac.jp
Background:
Liver cirrhosis causes peculiar systemic hemodynamics, and accurate evaluation of systemic hemodynamic state is important for cirrhotic recipients who underwent living donor liver transplantation (LDLT). We investigated the clinical advantages of a novel non-invasive method for measuring systemic hemodynamic parameters using indocyanine green (ICG).
Methods:
Twenty-eight LDLT recipients were evaluated. Simultaneous measurements of cardiac output (CO) using Swan-Ganz catheters and pulse dye densitometry (PDD) were performed every 12 hours after LDLT. A total of 155 sets of simultaneous CO measurements were obtained.
Results:
The CO values obtained by PDD correlated well with those obtained by the invasive catheter technique. In addition, none of the recipients developed any side-effects, and we verified the safety of repeated ICG injections. ICG is safe, even for repeated use over time in the same recipient. Moreover, PDD can measure the blood volume (BV).
Conclusions:
Since the cirrhotic systemic hemodynamics characterized by high CO and large BV remains, even after LDLT, the ability to measure CO and BV in a non-invasive, simple and real-time manner using PDD has advantages for cirrhotic LDLT recipients.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...