Location of a reflection site is elusive: consequences for the calculation of aortic pulse wave velocity
Berend E Westerhof1, Jeroen P van den Wijngaard, Joseph P Murgo
1BMEYE BV, Academic Medical Center, Amsterdam, The Netherlands. berend.westerhof@bmeye.com
Abstract:
Aortic pulse wave velocity (PWV), a measure of aortic stiffness, is an important indicator of cardiovascular risk. Derivation of PWV from uncalibrated proximal aortic or carotid pressure alone has practical advantages. However, when the time of return of the reflected wave, (Delta)t, is used to calculate PWV, inaccurate data are obtained. With aging PWV increases but (Delta)t hardly decreases, suggesting that the reflection site moves toward the periphery. We hypothesized that the forward and reflected waves in the distal aorta are not in phase, leading to an undefined reflection site. We derived forward and backward waves, at the entrance and distal end of a uniform tube, with length "L." With the tube closed at the end, forward and reflected waves are there in phase, and PWV=2L/(Delta)t. When the tube is ended with the input impedance of the lower body, forward and backward waves at its end are not in phase, and (Delta)t is increased, suggesting that the reflection site is further away (tube seems longer), and PWV calculated from 2L/(Delta)t is underestimated. Using an anatomically accurate model of the human arterial system, we show that the forward and backward waves in the distal aorta are not in phase. When aortic PWV increases, (Delta)t changes only little, and the reflection site appears to move to the periphery, similar to what is observed in humans. We conclude that to define the location of a reflection site is elusive and that PWV cannot be calculated from time of return of the reflected wave.
Related Concept Videos
Pulse Assessment Sites
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical indicator...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation