Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage

W Huda1, K M Ogden, M R Khorasani

  • 1Department of Radiology, Medical University of South Carolina, Charleston, SC 29425, USA. huda@musc.edu

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions01:15

Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions

PK–PD modeling has significantly influenced FDA regulatory decisions, particularly drug approval, dosage optimization, and labeling. These models integrate pharmacokinetics (PK) and pharmacodynamics (PD) to predict drug behavior and effects, aiding in optimizing dosing regimens and enhancing the probability of clinical trial success.One notable example is Nesiritide (Natrecor®), a recombinant human brain natriuretic peptide for treating acute decompensated congestive heart failure (CHF).
Pharmacodynamic Models: Linear Concentration–Effect Model01:15

Pharmacodynamic Models: Linear Concentration–Effect Model

The linear concentration–effect model, underpinned by the principle that pharmacological effect (E) is directly proportional to plasma drug concentration (C), emerges as a pivotal simplification of the Emax model for conditions where C is significantly less than EC50. This model portrays a linear trajectory of the concentration–effect relationship when drug levels are markedly below the EC50 threshold.Despite its inherent assumption of continuous effect augmentation with increasing drug...
Dose Response Curve: Conventional Versus Nonmonotonic01:21

Dose Response Curve: Conventional Versus Nonmonotonic

The correlation between a drug's dosage and its impact on a biological system is a cornerstone of pharmacology and toxicology. Conventional dose–response curves, which include graded and quantal relationships, are key to this understanding. Graded dose–response curves depict the spectrum of a biological reaction to different doses within an individual, indicating that as the drug dosage increases, so does the intensity of the response. On the other hand, quantal dose–response relationships...
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and the...