Related Experiment Video
Updated: Jul 2, 2026

Methods for Analyzing the Impacts of Natural Uranium on In Vitro Osteoclastogenesis
Published on: January 30, 2018
Uncertainty analysis of doses from inhalation of depleted uranium
M Puncher1, M R Bailey, J D Harrison
1Radiation Protection Division, Health Protection Agency Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot, OX11 0RQ, United Kingdom. matthew.puncher@hpa.org.uk
Abstract:
Measurements of uranium excreted in urine have been widely used to monitor possible exposures to depleted uranium (DU). This paper describes a comprehensive probabilistic uncertainty analysis of doses determined retrospectively from measurements of DU in urine. Parametric uncertainties in the International Commission on Radiological Protection (ICRP) Human Respiratory Tract Model (HRTM) and ICRP systemic model for uranium were considered in the analysis, together with uncertainties in an alternative model for particle removal from the lungs. Probability distributions were assigned to HRTM parameters based on uncertainties documented in ICRP Publication 66 and elsewhere, including the Capstone study of aerosols produced after DU penetrator impacts. Uncertainties in the uranium systemic model were restricted to transfer rates having the greatest effect on urinary excretion, and hence retrospective dose assessments, over the measurement times considered (10-10(4) d). The overall uncertainty on dose (the ratio of the upper and lower quantiles, q0.975/q0.025) was estimated to be about a factor of 50 at 10 days after intake and about a factor of 10 at 10(3)-10(4) d. The dose to the lung dominated the committed effective dose, with the lung absorption parameters, particularly the slow dissolution rate, ss, dominating the overall uncertainty. The median dose determined from a measurement of 1 ng DU, collected in urine in a 24-h period, varied from 0.1 microSv at 10 d to about 1 mSv at 10(4) d. Despite the large uncertainties, the upper q0.975 quantile for the assessed dose was below 1 mSv up to 5,000 d.
More Related Videos
09:18Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Microbial Bioremediation of Uranium
Uncertainty: Overview
Propagation of Uncertainty from Systematic Error