Related Experiment Video
Updated: Jul 2, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Population monitoring for acute exposure to 210Po
Jeri L Anderson1, Henry B Spitz, Robert D Daniels
1Division of Surveillance, Hazard Evaluations, and Field Studies (DSHEFS), National Institute for Occupational Safety and Health (NIOSH), Cincinnati, Ohio 45226, USA. JLAnderson@cdc.gov
Objective:
To investigate the feasibility of using single void urine samples to monitor internal radiation exposure of first responders and large populations int he event of a radiological incident involving the intentional dispersal of 210Po.
Methods:
Urinary excretion of 210Po was evaluated and organ absorbed and effective doses were calculated subsequent to an acute unit intake of 210Po.
Results:
210Po can be detected in single void urine samples at levels sufficient to detect effective dose below recommended limits. Minimum intakes of 210Po that would result in clinically significant effects were estimated.
Conclusions:
Collection and analysis of single void urine samples is adequate to identify persons who may be exposed in the event of a radiological emergency involving 210Po. Also, the first responder limit appears to be sufficiently protective to prevent clinically significant deterministic effects.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Holter Monitor: 24-Hour Monitoring
Biological Effects of Radiation