Related Experiment Video
Updated: Jul 2, 2026

Arterial Pouch Microsurgical Bifurcation Aneurysm Model in the Rabbit
Published on: May 14, 2020
Aneurysmal rupture during coiling: low incidence and good outcomes at a single large volume center
Jonathan L Brisman1, Yasunari Niimi, Joon K Song
1Center for Endovascular Surgery at Institute for Neurology and Neurosurgery, Roosevelt Medical Center, New York, New York, USA. jbrisman@solarishs.org
Objective:
To study the incidence and clinical outcomes of intraoperative aneurysm rupture (IOR) during endovascular coil embolization at a single large volume center and to review the literature on this subject to determine whether IOR rupture rate and mortality correlate with volume of aneurysms treated at a given center and years since the institution of Guglielmi detachable coils as a treatment modality.
Methods:
We reviewed the aneurysm database at the Center for Endovascular Surgery since its inception (1997-2003) and reviewed 600 consecutively treated intracranial aneurysms in which coiling was attempted. All patients who sustained an IOR were studied. Procedural and follow-up angiograms as well as clinical outcomes were retrospectively reviewed. A literature review was conducted.
Results:
Six patients (1.0%) experienced IOR (1.4% in acutely ruptured lesions, 0% in unruptured). All six had presented with diffuse subarachnoid hemorrhage (Fisher Grade 3) and in good clinical grade (Hunt & Hess Grades 1-3). One patient was rendered permanently disabled secondary to delay in controlling the IOR. All others were neurologically unchanged. A review of the literature revealed a trend in correlation between volume of aneurysms treated and IOR rate; no statistically significant correlation was found between volume of aneurysms treated or years since the introduction of GDC technology and IOR rates or mortality.
Conclusion:
IOR remains a serious risk of endosaccular coiling of intracranial aneurysms, with aneurysms presenting with subarachnoid hemorrhage at greater risk for this complication. This risk can be minimized with very low associated morbidity and mortality (incidence 1%, 17% morbidity, 0% mortality at our institution).
More Related Videos
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
Published on: September 8, 2023
11:58Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm IV: Nursing Management
Aneurysm I: Introduction
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations: