Changes in pulse oximetry after patent blue dye injection into the uterine cervix
Sabas Carlos Vieira1, Rodrigo Beserra Sousa, Marília Buenos Aires Cabral Tavares
1Universidade Federal do Piauí (UFPI), Rua Félix Pacheco 2159, Sala 305, Edifício Shecap, 64001-160, Teresina, Piauí, Brazil. sabas.vieira@uol.com.br
Background:
To evaluate changes in pulse oximetry readings in patients with cervical carcinoma after the injection of patent blue dye into the uterine cervix for sentinel lymph node detection.
Methods:
Fifty-six patients underwent radical hysterectomy and bilateral pelvic lymphadenectomy for the treatment of International Federation of Gynecology and Obstetrics stage I or II cervical cancer. Four milliliters of patent blue dye were injected into the cervix. On the eve of surgery, all patients also received an injection of Dextran 500 labeled with technetium 99 m (Tc-99 m Dextran, 600 to 800 muCi) into the cervix and subsequently underwent pelvic lymphoscintigraphy.
Results:
Of the 56 patients, 1 (1.79%) had an anaphylactic reaction, and in 13 (23.22%), pulse oximetry readings were <96%. The lowest median pulse oximetry reading in these patients was 87%. Pulse oximetry readings began to decrease between 2 and 10 minutes after patent blue dye injection into the cervix and lasted for approximately 5 minutes. No changes in blood pressure, heart rate, or electrocardiogram were found during the period in which this alteration was recorded by the pulse oximeter.
Conclusion:
The decrease in pulse oximetry readings after patent blue dye injection into the cervix was associated with larger tumors and tumors that surrounded the external cervical os.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: