Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 2, 2026

Microtensiometer for Confocal Microscopy Visualization of Dynamic Interfaces
08:05

Microtensiometer for Confocal Microscopy Visualization of Dynamic Interfaces

Published on: September 9, 2022

Multicell spinning drop interfacial tensiometer.

T R Fink1, D P Hearn

  • 1Atlantic Richfield Company, Dallas, Texas 75221.

The Review of Scientific Instruments
|February 1, 1978
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[The emergency room as a setting for clinical training].

Harefuah·1990
Same author

Quality of emergency room care during the Israel doctors' strike.

Public health·1984
Same author

Prosthetic valve hemolysis aggravated by gastrointestinal bleeding.

European journal of cardiology·1978
Same author

[An experimental program for the integration of community and hospital medical services].

Harefuah·1977
Same author

[Adriamycin in the treatment of primary carcinoma of the liver].

Harefuah·1976
Same author

Letter: The enthalpy of the "bulge" defect of imperfect nucleic acid helices.

Biopolymers·1975
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
Same journal

Bidirectional drive and multi-resolution adjustment across frequency bands in inertial impact piezoelectric motors via multimodal resonant vibration.

The Review of scientific instruments·2026
Same journal

A magnetic field sensor based on flaky Terfenol-D material and dual fiber grating.

The Review of scientific instruments·2026
Same journal

A novel E-field eight-way cavity combiner for high-power S-band applications.

The Review of scientific instruments·2026
Same journal

Constant radius blade spring suspended bench for vibration isolation.

The Review of scientific instruments·2026
Same journal

Qualification of infrared optical fibers and emitters for a spectrometer for in situ planetary exploration: Results from the TRIS (TRansmission and Illumination System) project.

The Review of scientific instruments·2026
See all related articles

This study details a new thermostated multicell spinning drop interfacial tensiometer. The instrument offers precise temperature control and simultaneous measurement of interfacial tensions for multiple liquid pairs.

Area of Science:

  • Physical Chemistry
  • Materials Science

Background:

  • Accurate measurement of interfacial tension is crucial for understanding fluid behavior.
  • Existing tensiometers may have limitations in temperature control, vibration, or sample throughput.

Purpose of the Study:

  • To describe the design and performance of a novel thermostated multicell spinning drop interfacial tensiometer.
  • To highlight key features enhancing measurement accuracy and efficiency.

Main Methods:

  • Utilized simple, reliable commercial components for instrument construction.
  • Incorporated +/-1°C thermostating and vibration reduction techniques.
  • Designed specialized cells to minimize gyrostatic equilibrium issues.

Main Results:

More Related Videos

Accurate Determination of the Equilibrium Surface Tension Values with Area Perturbation Tests
07:57

Accurate Determination of the Equilibrium Surface Tension Values with Area Perturbation Tests

Published on: August 30, 2019

Measurement of Aggregate Cohesion by Tissue Surface Tensiometry
12:49

Measurement of Aggregate Cohesion by Tissue Surface Tensiometry

Published on: April 8, 2011

Related Experiment Videos

Last Updated: Jul 2, 2026

Microtensiometer for Confocal Microscopy Visualization of Dynamic Interfaces
08:05

Microtensiometer for Confocal Microscopy Visualization of Dynamic Interfaces

Published on: September 9, 2022

Accurate Determination of the Equilibrium Surface Tension Values with Area Perturbation Tests
07:57

Accurate Determination of the Equilibrium Surface Tension Values with Area Perturbation Tests

Published on: August 30, 2019

Measurement of Aggregate Cohesion by Tissue Surface Tensiometry
12:49

Measurement of Aggregate Cohesion by Tissue Surface Tensiometry

Published on: April 8, 2011

  • The instrument demonstrates effective thermostating and reduced operational vibration.
  • Cells successfully mitigate problems associated with gyrostatic equilibrium.
  • The tensiometer can simultaneously measure interfacial tensions for six liquid pairs.
  • Conclusions:

    • The developed spinning drop interfacial tensiometer is a robust and efficient tool.
    • It offers enhanced capabilities for interfacial tension measurements in various scientific applications.