Improved technique for measuring intense pulsed ion beams by the nuclear activation method.
A E Blaugrund1, S J Stephanakis
1Naval Research Laboratory, Washington, D. C. 20375.
The Review of Scientific Instruments
|June 1, 1978
Summary
This study introduces a nuclear activation method to accurately measure high ion fluences. A specialized enclosure prevents target blowoff, improving measurement reliability for ion beam applications.
Area of Science:
- Nuclear physics
- Materials science
- Accelerator technology
Background:
- Accurate measurement of ion fluence is critical for materials modification and accelerator diagnostics.
- Traditional methods can be affected by target material loss due to high energy ion interactions.
Purpose of the Study:
- To present a novel technique for measuring very high ion fluences.
- To overcome limitations of existing methods, specifically target blowoff.
Main Methods:
- Utilizes the nuclear activation method for ion fluence determination.
- Employs a specially designed enclosure to contain the target during irradiation.
Main Results:
- The described technique enables reliable measurement of high ion fluences.
- The enclosure effectively mitigates adverse effects from target blowoff, ensuring data integrity.
Conclusions:
- This method provides a robust solution for accurate ion fluence measurement in demanding experimental conditions.
- The specialized enclosure is key to the success of the nuclear activation technique for high fluence applications.
Related Concept Videos
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Nuclear Overhauser Enhancement (NOE)
Irradiation of a spin-active nucleus causes an increase or decrease in the signal intensity of neighboring nuclei that are not necessarily chemically bonded or involved in J-coupling. This phenomenon, called the nuclear Overhauser enhancement (NOE), results from through-space interactions between the nuclear spins. The NOE effect decreases with increasing internuclear distance and is generally not observed beyond 4 angstroms. In NOE, dipole-dipole interactions between neighboring spin-active...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.