Related Experiment Video
Updated: Jul 2, 2026

11:54
Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
Multichannel scaling with an eight bit microcomputer
1Department of Materials Science and Mineral Engineering and Materials and Molecular Research Division, Lawrence Berkeley Laboratory, University of Californa, Berkeley, California 94720.
The Review of Scientific Instruments
|August 1, 1978
Abstract:
In this note a microcomputer-based system for multichannel scaling is described. This system relies on a combination of simple hardware with software support to achieve maximum cost effectiveness.
Related Concept Videos
Introduction to Scalers
Many familiar physical quantities can be specified completely by giving a single number and the appropriate unit. For example, "a class period lasts 50 min," or "the gas tank in my car holds 65 L," or "the distance between the two posts is 100 m." A physical quantity that can be specified completely in this manner is called a scalar quantity. The word "scalar" is a synonym for "number." Time, mass, distance, length, volume, temperature, and energy are some examples of scalar quantities.
Scalar...
Scalar...
Design Example: Capacitance Multiplier Circuit
In integrated circuit technology, a capacitance multiplier is often utilized to produce a larger capacitance value when a small physical capacitance falls short. This is achieved by a circuit that multiplies capacitance values by a factor of up to 1000, such that a 10-pF capacitor can replicate the performance of a 100-nF capacitor.
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.
Voltage Dividers
In electrical circuits, resistors can be connected in series, sequentially linked one after the other. In a series configuration, the same current flows through each resistor. Ohm's law is a fundamental principle to understand the behavior of resistors in series. It expresses the voltage across these resistors in terms of the current and resistance.
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
Kirchhoff's voltage law implies that the sum of the voltages across the resistors in series equals the source voltage. This means that the current...
Scaling
In designing and analyzing filters, resonant circuits, or circuit analysis at large, working with standard element values like 1 ohm, 1 henry, or 1 farad can be convenient before scaling these values to more realistic figures. This approach is widely utilized by not employing realistic element values in numerous examples and problems; it simplifies mastering circuit analysis through convenient component values. The complexity of calculations is thereby reduced, with the understanding that...
Design Example: Vintage Mixing Console
A sound engineer at a music company recently encountered a problem. The output from their newly acquired studio's vintage mixing console was too low for the requirements of modern recording equipment. To rectify this situation, the engineer decided to design an audio pre-amplifier using an operational amplifier (op-amp) to boost the signal level.
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Scale-Up Processes
The scale-up of microbial fermentation processes is essential in industrial biotechnology, allowing the transition from laboratory-scale experiments to commercial-scale production while aiming to maintain product yield and quality. This process requires meticulous adjustment of equipment design, process parameters, and contamination control strategies to accommodate increasing culture volumes.At the laboratory scale, cultures are typically maintained in 1 to 10-liter glass or autoclavable...