Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Rhodopsin--advances and perspectives.

Vision research·2006
Same author

[To see from light--biophysics of visual signal transduction].

Zeitschrift fur medizinische Physik·2002
Same author

Signaling states of rhodopsin: absorption of light in active metarhodopsin II generates an all-trans-retinal bound inactive state.

The Journal of biological chemistry·2001
Same author

Activation of rhodopsin: new insights from structural and biochemical studies.

Trends in biochemical sciences·2001
Same author

Mechanism of rhodopsin activation as examined with ring-constrained retinal analogs and the crystal structure of the ground state protein.

The Journal of biological chemistry·2001
Same author

Maximal rate and nucleotide dependence of rhodopsin-catalyzed transducin activation: initial rate analysis based on a double displacement mechanism.

The Journal of biological chemistry·2000
Same journal

Erratum: "Highly versatile, two-color setup for high-order harmonic generation using spatial light modulators" [Rev. Sci. Instrum. 95, 073002 (2024)].

The Review of scientific instruments·2026
Same journal

Thermal correction method for accurate performance evaluation of micro-thermoelectric coolers.

The Review of scientific instruments·2026
Same journal

Correcting the energy-dependent asymmetry in low-energy muon spin rotation.

The Review of scientific instruments·2026
Same journal

Fiber-integrated acousto-optic-modulator-based phase-controlled Rydberg atomic electrometer.

The Review of scientific instruments·2026
Same journal

A top-loading point-contact spectroscopy probe with in-situ sample exchange for dilution refrigerators.

The Review of scientific instruments·2026
Same journal

Investigation of plasma characteristics in a developed large-diameter, low-aspect ratio, radio frequency plasma source with a flat spiral antenna.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Jul 2, 2026

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
07:16

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

Published on: September 27, 2019

Differential light detector.

K P Hofmann1, D Emeis

  • 1Institut fur Biophysik und Strahlenbiologie, Albert Ludwigs Universitat Freiburg, Albertstrasse 23, D-7800 Freiburg, West Germany.

The Review of Scientific Instruments
|February 1, 1979
PubMed
Summary
This summary is machine-generated.

This study introduces a sensitive differential light detector using silicon photovoltaic diodes for precise intensity difference detection. The device minimizes noise and optimizes signal transfer for enhanced performance.

More Related Videos

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

Light Preference Assay to Study Innate and Circadian Regulated Photobehavior in Drosophila Larvae
07:14

Light Preference Assay to Study Innate and Circadian Regulated Photobehavior in Drosophila Larvae

Published on: April 20, 2013

Related Experiment Videos

Last Updated: Jul 2, 2026

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis
07:16

Light Spot-Based Assay for Analysis of Drosophila Larval Phototaxis

Published on: September 27, 2019

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
09:51

TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples

Published on: September 19, 2025

Light Preference Assay to Study Innate and Circadian Regulated Photobehavior in Drosophila Larvae
07:14

Light Preference Assay to Study Innate and Circadian Regulated Photobehavior in Drosophila Larvae

Published on: April 20, 2013

Area of Science:

  • Optoelectronics
  • Sensor Technology

Background:

  • Differential light detection is crucial for various scientific and industrial applications.
  • Existing methods may lack the sensitivity required for detecting minute intensity variations.

Purpose of the Study:

  • To develop and describe a novel, highly sensitive differential light detector.
  • To optimize the device for detecting small differences in light intensity.

Main Methods:

  • Utilized two antiparallel silicon photovoltaic diodes.
  • Incorporated a current-to-voltage converter for signal processing.
  • Analyzed noise and signal transfer characteristics.

Main Results:

  • The developed detector demonstrates high sensitivity to small intensity differences.
  • Noise and signal transfer features were characterized, confirming device optimization.
  • An application example validated the detector's practical utility.

Conclusions:

  • The described differential light detector offers a sensitive and effective solution for intensity difference measurements.
  • The design is optimized for performance, with noise and signal transfer considerations addressed.
  • The device has potential applications in fields requiring precise light detection.