Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty
Kyung Soon Park1, Sanket R Diwanji, Hyung Keun Kim
1Center for Joint Disease, Chonnam National University Hwasun Hospital, Ilsim-Ri, Hwasun-Eup, Hwasun-Gun, Jeonnam 519-809, South Korea.
Abstract:
Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.