Related Experiment Video
Updated: Jul 2, 2026

Preparation and Characterization of Individual and Multi-drug Loaded Physically Entrapped Polymeric Micelles
Published on: August 28, 2015
Robust open tubular layer of S-ketoprofen imprinted polymer for chiral LC separation
Shabi Abbas Zaidi1, Won Jo Cheong
1Department of Chemistry, Nano Fine Center and Institute of Basic Research, Inha University, Incheon, South Korea.
Abstract:
This study is about the preparation of an open tubular capillary column of molecularly imprinted polymer (MIP) and its application to chiral separation by microLC. A non-covalent in-situ molecular imprinting polymerization protocol was used to synthesize the S-ketoprofen MIP. A special procedure was employed to secure formation of an open tubular and rigid MIP layer in a silica capillary of 100 microm id. The capillary was filled with the reaction mixture, sealed, and placed in a water bath at 50 degrees C for 3 h. Then it was flushed with a 0.5 MPa nitrogen flow for 5 min, and was again placed in the water bath for 2 h to complete MIP formation. Methacrylic acid (MAA) has been known to be an inefficient functional monomer in preparation of MIP of an acid molecule. However, MAA was used with ethylene glycol dimethacrylate in preparation of the S-ketoprofen MIP in this study. The open tubular structure and the microLC mode of separation enabled free optimization without any restriction, thus a very good resolution (R=4.7) of ketoprofen enantiomers was achieved when a mobile phase composed of 30% acetonitrile and 70% acetate buffer at pH 4.5 was used with 5 mbar inlet pressure. This may be partially attributed to the open tubular structure of our MIP, enabling low column back-pressure and free optimization of eluent composition, as well as to the small capillary dimensions. Our MIP capillary column also showed some versatility in chiral separation, thus a good chiral separation was observed for naproxen, ibuprofen, and fenoprofen enantiomers.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...