Related Experiment Video
Updated: Jul 2, 2026

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Aptamer-based electrochemical sensors that are not based on the target binding-induced conformational change of
Ying Lu1, Ningning Zhu, Ping Yu
1Beijing National Laboratory for Molecular Sciences, Institute of Chemistry, the Chinese Academy of Sciences (CAS), Beijing 100080, China.
Abstract:
This study describes a new kind of aptamer-based electrochemical sensor that is not based on the target binding-induced conformational change of the aptamers by using a 15-mer thrombin-binding aptamer (5'-GGTTGGTGTGGTTGG-3') as the model oligonucleotide. The sensors are developed by first self-assembling the aptamer (i.e. a thrombin-binding aptamer) onto an Au electrode and then hybridizing the assembled aptamer with a ferrocene (Fc)-labeled short aptamer-complementary DNA oligonucleotide to form an electroactive double-stranded DNA (ds-DNA) oligonucleotide onto the Au electrode. The binding of the target (i.e. thrombin) towards the aptamer essentially destroys the Watson-Crick helix structure of the ds-DNA oligonucleotide assembled onto the electrode and leads to the dissociation of the Fc-labeled short complementary DNA oligonucleotide from the electrode surface to the solution, resulting in a decrease in the current signal obtained at the electrode, which can be used for the determination of the target. With the thrombin-binding aptamer as the model oligonucleotide, the current decrease obtained with the aptamer-based electrochemical sensors is linear with the concentration of thrombin within the concentration range from 0 to 10 nM (DeltaI/nA = 6.7C(thrombin)/nM + 2.8, gamma = 0.975). Unlike most kinds of existing aptamer-based electrochemical sensor, the electrochemical aptasensors demonstrated here are not based on the conformational change of the aptamers induced by the specific target binding. Moreover, the aptasensors are essentially label-free and are very responsive toward the targets. This study may pave a facile and general way to the development of aptamer-based electrochemical sensors.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.