[Fatalities due to nitrous oxide. Complications from mistakes in nitrous oxide supply]
1Universitätsklinik für Anästhesiologie und Intensivmedizin, Medizinische Universität Innsbruck, Anichstr. 35, 6020 Innsbruck, Osterreich. holger.herff@uki.at
Abstract:
Despite inspiratory oxygen fraction measurement being regulated by law in the European norm EN 740, fatal errors in nitrous oxide delivery still occur more frequently than expected, especially after construction or repair of gas connection tubes. Therefore, if nitrous oxide is to be used further in a hospital, all technical measures and system procedures should be employed to avoid future catastrophes. Among these are measurement of the inspiratory oxygen fraction (F(I)O(2)) and an automatic limitation of nitrous oxide. Also all anaesthetists involved should be informed about repair or construction of central gas supply tubes. Additionally, more awareness of this problem in daily routine is necessary. Furthermore, a system of detecting and analysing errors in anaesthesia has to be improved in each hospital as well as in the anaesthesia community as a whole. Measures for a better "error culture" could include data exchange between different critical incident reporting systems, analysis of closed claims, and integration of medical experts in examination of recent catastrophes.
Related Concept Videos
Inhalational Anesthetics: Overview
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
2° Amines to N-Nitrosamines: Reaction with NaNO2
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: