Related Experiment Video
Updated: Jul 2, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Determinants of tidal volumes with adaptive support ventilation: a multicenter observational study
Dave A Dongelmans1, Denise P Veelo, Alexander Bindels
1Department of Intensive Care Medicine, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands. d.a.dongelmans@amc.uva.nl
Introduction:
In the present study, we investigated the behavior of adaptive support ventilation (ASV) in patients after cardiothoracic surgery. We determined tidal volumes (Vt) and factors that influence Vt with this mode of microprocessor-controlled mechanical ventilation (MV).
Methods:
This was a prospective, multicenter, observational study in three Dutch intensive care units over a 5-mo period. MV data were collected during steady-state after arrival in the intensive care unit.
Results:
Data were collected for 346 consecutive patients after cardiothoracic surgery: 262 patients weaned with ASV, and 84 patients weaned with pressure-controlled/pressure-support MV. With ASV the mean (+/- sd) Vt expressed per kilogram actual body weight was 7.1 +/- 1.6 mL. Expressed per kilogram ideal body weight (IBW), Vt was 8.3 +/- 1.5 mL. In patients with a correctly set body weight (SBW) (i.e., the IBW), Vt was 8.1 +/- 1.4 mL/kg. With pressure-controlled/pressure-support-MV Vt was 7.3 +/- 1.4 mL/kg IBW (P < 0.001 vs ASV). Multivariate logistic regression analysis showed Vt with ASV to be dependent on only two parameters: respiratory rate and the correctness of SBW.
Conclusions:
Vt with ASV seems to be dependent on two parameters: respiratory rate and the correctness of SBW. The first factor is not clinically important because respiratory rate is automatically chosen by the microprocessor. The second factor is clinically important because it is the only factor that can be influenced by the operator. Our data show the importance of setting the correct weight with ASV. With ASV, Vt are >8 mL/kg IBW in a substantial number of patients. Randomized clinical trials should be performed to compare ASV with other ventilation modes.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...