Related Experiment Video
Updated: Jul 2, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Acetabular reconstruction with human and bovine freeze-dried bone grafts and a reinforcement device
Ricardo Rosito1, Carlos Roberto Galia, Carlos Alberto Souza Macedo
1Orthopedics Department-Tissue Bank, Hospital de Clínicas de Porto Alegre, Faculdade de Medicina, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil. ricardo@rosito.com.br
Background:
This is a cohort trial (1997-2005) of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG) and a reinforcement device.
Objective:
To compare clinical/radiographic graft incorporation capability between cancellous bone grafts.
Patients/Methods:
There were two groups: I (n=26) receiving human grafts and II (n=25) receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d'Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn's et al. criteria for radiographic bone incorporation.
Results:
No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424).
Conclusion:
The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty.