Phenotypic detection of inducible clindamycin resistance among Staphylococcus aureus isolates by using the lower

G S Ajantha1, Raghavendra D Kulkarni, Jeevan Shetty

  • 1Department of Microbiology, SDM College of Medical Sciences and Hospital, Sattur, Dharwad - 580 009, Karnataka, India. ajju_dwd@rediffmail.com

Abstract

Insights

A closer D-test disk distance (15 mm) significantly improves the detection of inducible clindamycin resistance (iMLS B) in Staphylococcus aureus. This enhanced detection is crucial for preventing treatment failures in MRSA infections.

Area of Science:

  • Clinical microbiology
  • Antimicrobial resistance
  • Infectious diseases

Background:

  • Clindamycin is a key antibiotic for Staphylococcus aureus, including MRSA.
  • Inducible clindamycin resistance (iMLS B) impacts treatment efficacy.
  • Accurate detection of iMLS B is vital for antimicrobial susceptibility testing.

Purpose of the Study:

  • To determine the rate of inducible clindamycin resistance in S. aureus isolates.
  • To compare the D-test using average vs. lower limit inter-disk distances.
  • To optimize the D-test for iMLS B detection.

Main Methods:

  • Evaluated 51 erythromycin-resistant, clindamycin-susceptible S. aureus isolates.
  • Performed Disk approximation test (D-test) with 21±1 mm and 15 mm inter-disk distances.
  • Utilized Z-test for statistical analysis.

Main Results:

  • The 21±1 mm D-test identified 49% inducible clindamycin resistance.
  • The 15 mm D-test detected 14% more iMLS B strains.
  • The 15 mm distance showed a significant advantage for iMLS B detection.

Conclusions:

  • High incidence of inducible clindamycin resistance (63%) necessitates accurate detection.
  • The 15 mm inter-disk distance D-test is recommended for reliable iMLS B identification.
  • Optimized D-test use prevents therapeutic failures in S. aureus infections.