UV treatment of microorganisms on artificially-contaminated surfaces using excimer and microwave UV lamps
N Christofi1, M A Misakyan, G G Matafonova
1Pollution Research Unit, School of Life Sciences, Napier University, Edinburgh, Scotland, UK. n.christofi@napier.ac.uk
Abstract:
An XeBr excilamp having a peak emission at 283 nm, and microwave UV lamps with peak emissions at 253.7 nm that also generate ozone, have been tested for ability to eradicate high populations of microbial vegetative cells and spores (of bacteria and fungi) artificially added to filter surfaces. The study examined the energy required to completely eradicate large populations on filter surfaces. It was found that both the excilamp and microwave UV lamps were effective at killing large populations on surfaces with killing efficiency dependant on the type of organism, and, whether present in its vegetative or spore forms. The main killing factor is UV radiation following short treatment times. It is considered that for longer irradiation periods that are required to facilitate complete destruction of surface microorganisms, ozone and other oxidising species produced by microwave UV lamps would act to enhance microbial destruction.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Microbial Bioremediation of Uranium
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Microbial Wastewater Treatment