Related Experiment Video
Updated: Jul 2, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Adenosine stress rubidium-82 PET/computed tomography in patients with known and suspected coronary artery disease
Fabio P Esteves1, Rupan Sanyal, Jonathon A Nye
1Department of Radiology, Emory University School of Medicine, Atlanta, Georgia 30322, USA.
Background:
Integrated positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for myocardial perfusion imaging (MPI). However, there is a potential for increased imaging artifact compared with standard PET due to the different temporal resolution of PET and CT. We reviewed the diagnostic accuracy of adenosine stress Rb myocardial perfusion PET/CT to detect obstructive coronary artery disease (CAD) on invasive angiography at our institution.
Methods And Results:
Seventy-five patients were included, 23 (13 men, mean age 55.8+/-11.8 years) with low likelihood of CAD and 52 (28 men, mean age 67.1+/-11.4 years) with intermediate to high pretest probability of disease. Coronary angiography was performed only in the latter 52 patients on average within 17 days of the MPI study. The test characteristics of PET/CT MPI were assessed using a threshold of >or=50 and >or=70% stenosis in one or more major coronary artery on invasive angiography. Dedicated software was used for registration, processing, and interpretation. Consensus interpretation of the tomographic PET slices using a 4-point scale (1=definitely normal, 2=probably normal, 3=probably abnormal, 4=definitely abnormal) was done by two readers blinded to clinical information.
Results:
All MPI studies in the 23 low likelihood patients were normal. In the remaining 52 patients using a stenosis severity>or=50%, global sensitivity and specificity, negative and positive predictive value for detection of CAD were 86, 100, 57, and 100%. Using a stenosis severity>or=70%, these values changed to 90, 83, 71, and 87%.
Conclusion:
Adenosine stress Rb MPI using PET/CT with manual registration demonstrates diagnostic accuracy comparable with that of traditional PET MPI.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Dysrhythmias V: Evaluating Dysrhythmias